HS Code : | 9028.20 | |
|---|
CN Code : | 9028.20.••.•• | |
|---|
BTI Reference :
Issuing Country :
GERMANY
Date Of Issue : 09.Nov.2026 - 08.Nov.2029
Ultrasound water meter with MID conformity, consisting of a technically designed pipe section with flanges or external threads, integrated reflectors for ultrasound signal redirection, two ultrasound transducers, a temperature sensor for compensation, and a fixed cuboid housing (electronics module) with LCD display, optical button, microcontroller, A/D converter, non-volatile memory, wireless transmission module, optical interface, two fixed lithium batteries, and other electronic components. The pipe section and electronics module are mechanically sealed by a manufacturer's seal. It measures water flow using the ultrasound time-of-flight difference method, with transducers operating bidirectionally as both sender and receiver. The microprocessor converts flow velocity into flow rates (e.g., m³/h) and displays total volume (e.g., m³). Data is stored and retrievable via display or wireless transmission for billing purposes.
Description auto translated : Ultrasonic water meter with MID conformity, available in various configurations, essentially consisting of a specifically shaped pipe element (pipeline section) manufactured according to technical drawings, equipped with flanges or external threads (depending on configuration), integrated reflectors for ultrasonic signal redirection, two ultrasonic transducers (transducer pair) connected to the pipe element, a temperature sensor for temperature compensation, a fixed cuboid housing (electronics module) attached to the pipe element containing an LCD display, an optical button, a microcontroller, an A/D converter, non-volatile memory, a radio module for remote reading, an optical interface, two fixed lithium batteries, and other electrical and electronic components. The pipe element and electronics module are mechanically sealed by a manufacturer-applied housing seal. The water meter is integrated into the water supply line via the pipeline section to measure the flow velocity of the water using the ultrasonic time-of-flight difference method. For this purpose, the ultrasonic transducers operate in bidirectional pulse mode, serving both as transmitters and receivers. The microprocessor converts the flow velocity into flow rate values (e.g., m³/h) and displays the total volume as a cumulative count or point-in-time value (e.g., m³). Flow data and consumption volumes are stored and can be retrieved at any time via the display. Additionally, data is transmitted wirelessly—e.g., to the metering service provider or water utility (including via passing vehicles)—for billing purposes. The key distinguishing feature is secure, legally compliant consumption measurement (metering function). The product is classified as a 'liquid flow meter'.
Original Description: Ultraschall-Wasserzähler mit MID-Konformität, in verschiedenen Ausführungen, im Wesentlichen bestehend aus einem spezifisch geformten, nach technischer Zeichnung gefertigten Rohrelement (Rohrleitungsabschnitt) mit Flanschen oder Außengewinden (je nach Ausführung) und integrierten Reflektoren zur Ultraschall-Signalumlenkung sowie zwei mit dem Rohrelement verbundenen Ultraschallwandlern (Wandler-Paar), einem Temperatursensor zur Temperaturkompensation, einem fest am Rohrelement verbauten quaderförmigen Gehäuse (Elektronikmodul) mit einem LCD, einem optischen Taster, einem Mikrocontroller, einem A/D-Wandler, einem nichtflüchtigen Speicher, einem Funkmodul zur Fernauslese, einer optischen Schnittstelle, zwei festen Lithium-Batterien sowie weiteren elektrischen und elektronischen Bauteilen.
Das Rohrelement und das Elektronikmodul sind durch eine herstellerseitige Gehäuse- plombe mechanisch versiegelt.
Der Wasserzähler wird mittels des Rohrleitungsabschnitts in die Wasserleitung integriert, um unter Anwendung des Ultraschall-Laufzeitdifferenzverfahrens die Strömungsgeschwindigkeit des Leitungswassers zu ermitteln.
Hierzu arbeiten die Ultraschallwandler im bidirektionalen Impuls-Betrieb, indem beide sowohl als Sender als auch als Empfänger dienen.
Der Mikroprozessor wandelt die Strömungsgeschwindigkeit in Durchflusswerte (z.B. m³/h) um und hält das Gesamtvolumen als Zählwert/Stichtagswert (z.B. m³) vor.
Die Durchflussdaten und Verbrauchsmengen werden gespeichert und können jederzeit am Display abgerufen werden.
Zudem werden die Daten per Funk z.B. an den Messdienstleister oder Wasserversorger (auch mittels vorbeifahrenden Fahrzeugs) zu Abrechnungszwecken ausgegeben.
Kennzeichnende Hauptfunktion ist die rechtssichere Verbrauchsmengenerfassung (Zählfunktion).
Die Ware wird als "Flüssigkeitszähler" eingereiht.